Просмотреть запись

Detectability of flat microdefects in radiographic images obtained using linear microfocus bremsstrahlung source based on 18 MeV betatron with narrow target inside

Электронный архив ТПУ

Информация об архиве | Просмотр оригинала
 
 
Поле Значение
 
Заглавие Detectability of flat microdefects in radiographic images obtained using linear microfocus bremsstrahlung source based on 18 MeV betatron with narrow target inside
 
Автор Rychkov, Maksim Mikhailovich
Kaplin, Valery Viktorovich
Smolyanskiy, Vladimir Aleksandrovich
 
Тематика микродефекты
рентгенография
изображения
микрофокусные источники
тормозные излучения
бетатроны
мишени
микровключения
 
Описание For the determination of ability of microfocus Bremsstrahlung (Bs) source based on B-18 betatron to detect flat microgaps and microinclusions in heavy material products the investigations were carried out. The radiographic images of 10 [mu]m gaps and 13 [mu] m tantalum (Ta) foil into steel bulk which were oriented at different angles with respect to the direction of radiation were investigated. The assembly of four steel blocks having 10 [mu]m gaps between their neighbor surfaces was placed on goniometer. The 13 [mu]m Ta foil having the length of 4 mm along radiation beam was mounted in a plastic holder which was also placed on the goniometer. For modeling narrow gaps and thin inclusions inside the bulk of steel detail, the experimental samples were placed before a thick steel plate. The radiographic images of the samples were obtained with a 2.4-fold magnification at different orientations of narrow gaps and Ta foil with respect to the radiation beam and at the thick steel plates of different thicknesses. The results illustrate high sensitivity of detecting of the microgaps inside steel bulk and flat microinclusions from heavy material in the bulk of detail made from a lighter material due to the microfocus of Bs source.
 
Дата 2019-11-29T05:21:24Z
2019-11-29T05:21:24Z
2019
 
Тип Conference Paper
Published version (info:eu-repo/semantics/publishedVersion)
Conference paper (info:eu-repo/semantics/conferencePaper)
 
Идентификатор Rychkov M. M. Detectability of flat microdefects in radiographic images obtained using linear microfocus bremsstrahlung source based on 18 MeV betatron with narrow target inside / M. M. Rychkov, V. V. Kaplin, V. A. Smolyanskiy // Journal of Physics: Conference Series. — 2019. — Vol. 1327 : Innovations in Non-Destructive Testing (SibTest 2019) : V International Conference, 26–28 June 2019, Yekaterinburg, Russia : [proceedings]. — [012014, 6 р.].
http://earchive.tpu.ru/handle/11683/57045
10.1088/1742-6596/1327/1/012014
 
Язык en
 
Права Open access (info:eu-repo/semantics/openAccess)
 
Издатель IOP Publishing