Potentiometric Sensor Based on Layered Pillar[6]arene—Copper Composite
Электронный научный архив УРФУ
Информация об архиве | Просмотр оригиналаПоле | Значение | |
Заглавие |
Potentiometric Sensor Based on Layered Pillar[6]arene—Copper Composite
|
|
Автор |
Sorvin, M.
Galimzyanova, G. Evtugyn, V. Ivanov, A. Shurpik, D. Stoikov, I. Evtugyn, G. |
|
Тематика |
COPPER DETERMINATION
PILLAR[6]ARENE POLYANILINE POTENTIOMETRIC SENSOR SOLID-CONTACT SENSOR |
|
Описание |
A solid-contact potentiometric sensor has been developed on the basis of glassy carbon electrode covered with electropolymerized polyaniline and alternatively layered pillar[6]arene and Cu2+ ions films. The assembly of the surface layer was confirmed by surface plasmon resonance measurements. The number of deposited layers was selected to reach better analytical characteristics for Cu2+ determination. It was shown that better results were achieved by using five layers, the upper one consisting of the macrocycle. The addition of covering layers for polyelectrolytes (Nafion, poly(styrene sulfonate)) and Cu2+ ions did not improve sensor performance. The potentiometric sensor made it possible to determine Cu2+ ions in neutral and weakly acidic media with a linear range of the concentrations, from 3.0 μM to 10.0 mM (limit of detection 3.0 μM). The applicability of the sensor in real sample assays was confirmed by the determination of Cu2+ ions in copper vitriol, Bordeaux mixture, and polyvitamin-mineral pills of “Complivit” during an atomic emission spectroscopy analysis. © 2022 by the authors.
Russian Science Foundation, RSF: 22-13-00070 This research was funded by the Russian Science Foundation, grant number 22-13-00070. |
|
Дата |
2024-04-05T16:37:37Z
2024-04-05T16:37:37Z 2023 |
|
Тип |
Article
Journal article (info:eu-repo/semantics/article) |info:eu-repo/semantics/publishedVersion |
|
Идентификатор |
Sorvin, M, Galimzyanova, G, Evtugyn, V, Ivanov, A, Shurpik, D, Stoikov, I & Evtugyn, G 2023, 'Potentiometric Sensor Based on Layered Pillar[6]arene—Copper Composite', Chemosensors, Том. 11, № 1, 12. https://doi.org/10.3390/chemosensors11010012
Sorvin, M., Galimzyanova, G., Evtugyn, V., Ivanov, A., Shurpik, D., Stoikov, I., & Evtugyn, G. (2023). Potentiometric Sensor Based on Layered Pillar[6]arene—Copper Composite. Chemosensors, 11(1), [12]. https://doi.org/10.3390/chemosensors11010012 2227-9040 Final All Open Access, Gold https://www.scopus.com/inward/record.uri?eid=2-s2.0-85146805101&doi=10.3390%2fchemosensors11010012&partnerID=40&md5=cfe0ec1d807c86abb2d73936e55f5797 https://www.mdpi.com/2227-9040/11/1/12/pdf?version=1671759764 http://elar.urfu.ru/handle/10995/131047 10.3390/chemosensors11010012 85146805101 000914462500001 |
|
Язык |
en
|
|
Связанные ресурсы |
info:eu-repo/grantAgreement/RSF//22-13-00070
|
|
Права |
Open access (info:eu-repo/semantics/openAccess)
cc-by https://creativecommons.org/licenses/by/4.0/ |
|
Формат |
application/pdf
|
|
Издатель |
MDPI
|
|
Источник |
Chemosensors
Chemosensors |
|