Описание A solid-contact potentiometric sensor has been developed on the basis of glassy carbon electrode covered with electropolymerized polyaniline and alternatively layered pillar[6]arene and Cu2+ ions films. The assembly of the surface layer was confirmed by surface plasmon resonance measurements. The number of deposited layers was selected to reach better analytical characteristics for Cu2+ determination. It was shown that better results were achieved by using five layers, the upper one consisting of the macrocycle. The addition of covering layers for polyelectrolytes (Nafion, poly(styrene sulfonate)) and Cu2+ ions did not improve sensor performance. The potentiometric sensor made it possible to determine Cu2+ ions in neutral and weakly acidic media with a linear range of the concentrations, from 3.0 μM to 10.0 mM (limit of detection 3.0 μM). The applicability of the sensor in real sample assays was confirmed by the determination of Cu2+ ions in copper vitriol, Bordeaux mixture, and polyvitamin-mineral pills of “Complivit” during an atomic emission spectroscopy analysis. © 2022 by the authors.
Russian Science Foundation, RSF: 22-13-00070
This research was funded by the Russian Science Foundation, grant number 22-13-00070.
 
Дата 2024-04-05T16:37:37Z
2024-04-05T16:37:37Z
2023
 
Тип Article
Journal article (info:eu-repo/semantics/article)
|info:eu-repo/semantics/publishedVersion
 
Идентификатор Sorvin, M, Galimzyanova, G, Evtugyn, V, Ivanov, A, Shurpik, D, Stoikov, I & Evtugyn, G 2023, 'Potentiometric Sensor Based on Layered Pillar[6]arene—Copper Composite', Chemosensors, Том. 11, № 1, 12. https://doi.org/10.3390/chemosensors11010012
Sorvin, M., Galimzyanova, G., Evtugyn, V., Ivanov, A., Shurpik, D., Stoikov, I., & Evtugyn, G. (2023). Potentiometric Sensor Based on Layered Pillar[6]arene—Copper Composite. Chemosensors, 11(1), [12]. https://doi.org/10.3390/chemosensors11010012
2227-9040
Final
All Open Access, Gold
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85146805101&doi=10.3390%2fchemosensors11010012&partnerID=40&md5=cfe0ec1d807c86abb2d73936e55f5797
https://www.mdpi.com/2227-9040/11/1/12/pdf?version=1671759764
http://elar.urfu.ru/handle/10995/131047
10.3390/chemosensors11010012
85146805101
000914462500001
 
Язык en
 
Связанные ресурсы info:eu-repo/grantAgreement/RSF//22-13-00070
 
Права Open access (info:eu-repo/semantics/openAccess)
cc-by
https://creativecommons.org/licenses/by/4.0/
 
Формат application/pdf
 
Издатель MDPI
 
Источник Chemosensors
Chemosensors